ESRA (Ecklund-Slip-Ring-Assembly)
Several types of agitating retorts require the use of multiple circuit
slip ring assemblies at the end of a rotating shaft
to conduct thermocouple
signals from a rotating to stationary mode.
Such devices can be very
troublesome if foreign metals (not thermocouple metals) are part of the
circuit and/or temperature differentials exist across the slip ring
assembly.
Only thermocouple materials are used in the conductive circuits
and the unit is mounted to isolate the assembly from the end of the hot
retort shaft to minimize temperature differentials.
The rotor shaft is
mounted on sealed ball bearings for durability.
Though the 16 circuit unit
is considered standard, we can provide the slip ring assembly in any size up
to 32 circuits. The design of the unit permits installation on virtually any
style of rotating retort with minimum difficulty.
ESR-HUB
This is an 18 circuit hub for installation on the FMC Steritort.
The unit
comes with 18, S-31 female connectors mounted in the hub.
This permits the
use of up to 18 rotary leads instead of the standard six.
The design
incorporates a 1 1/4” NPT stainless steel pipe nipple which threads into the
shaft of the FMC Steritort.
S-28 - Rotary Contactor
For use in conducting heat penetration tests in rolling cans in FMC
Steritorts.
The rotating parts are small in diameter to reduce frictional
torque.
The rotor may be easily removed for cleaning by removing a snap ring.
No
adjustments are necessary on re-assembly.
The contactor is supplied with a
34” (0.86 meters) wire and locking connector to connect into the hub of the
Steritort, and can be used with any style Ecklund thermocouple, but CNS and
C-2 types are recommended.